SANITARY TURBINE FLOWMETER FOR
PROCESS LIQUID MEASUREMENT
The Hoffer Sanitary Design Turbine flowmeter is designed and
manufactured to be compliant with the ASME Bioprocessing Equipment
Standard BPE-2012 for measurement of process liquids where high
sanitary standards are required. ASME-BPE-2012 is the leading
Standard on how to design and build equipment used in the production
of biopharmaceuticals. This series includes 11 sizes, ¼” to 3” with
standard Tri-Clamp™ fittings, covering flow rates for 0.35 to 650 GPM.c5a373909543d8102a5d4444120bf5e1_rDLyeSN1wfAIScpfxhBMgMwcjZO.jpg

Sanitary Flowmeter
증류수, 약품, 음료수라인 
 
청결함을 유지해야하는 증류수, 의약품, 음용수 라인에서 사용합니다.
정밀도는 HO liquid 시리즈와같은 +/-0.5% of reading이며 클램프타입의 체결방식으로 설치 및 분리가 용이합니다.

 

주요사양
 
크기 : 1/4"~3"(0.35 to 650GPM)
최대 허용 측정범위(Overrange) : 150% of maximum flow(Intermittently).
선형성(Linearity) : +/- 0.5% of reading or better
재현성(Repeatability) : +/- 0.1% of reading or better
허용 온도범위 : 기본 4℃ to 167℃
허용 압력손실(Pressure Drop Characteristics) : 4 to 5 psi at maximum linear flow rate at one CSTK.
Bearing Style :Hard Carbon Composite Sleeve Bearing(Standard)
Material : Body 316/316L dual rated Stainless Steel, Consult with applications
 Rotor is 17.4PH Stainless Steel.
품질인증
PED-CE : PED-CE mard required for Europe requires the operating temperature and
pressure be given and will be marked on the housing
SEP-CE : Sound endineering practics
CE : CE mark required for Europe
EXP : CSA Explosio-proof Certification
적용가능한 트랜스미터 : CAT1, CAT2, CAT3, HIT2A, HRT1, NOVA Flow Computer 
 
 