분동세척관련 OIML기술기준

 

 

 Cleaning weights

 

 

 

 

 

It is important to clean weights before any measurements are made because the cleaning process may change the mass of the weight. Cleaning should not remove any significant amounts of weight material. Weights should be handled and stored in such a way that they stay clean. Before calibration, dust and any foreign particles shall be removed. Care must be taken not to change the surface properties of the weight (i.e. by scratching the weight). 

 

 

If a weight contains significant amounts of dirt that cannot be removed by the methods cited above, the weight or some part of it can be washed with clean alcohol, distilled water or other solvents. Weights with internal cavities should normally not be immersed in the solvent to avoid the possibility that the fluid will penetrate the opening. If there is a need to monitor the stability of a weight in use, the mass of the weight should, if possible, be determined before cleaning.

 

 

 

After weights are cleaned with solvents they must be stabilized for the times given in Table B.1.

 

 

 

Table B.1 Stabilization time after cleaning

 

 

 

Weight class

E1

E2

F1

F2 to M3

After cleaning with alcohol

7–10 days

3–6 days

1–2 days

1 hour

After cleaning with distilled water

4–6 days

2–3 days

1 day

1 hour

 

 

 

 

 

Thermal stabilization

 

 

Prior to performing any calibration tests, the weights need to be acclimated to the ambient conditions of the labo- ratory. In particular, weights of classes E1, E2 and F1 should be close to the temperature in the weighing area.

 

B.4.3.1 The mandatory minimum times required for temperature stabilization (depending on weight size, weight class and on the difference between the initial temperature of the weights and the room temperature in the labora- tory) are shown in Table B.2. As a practical guideline, a waiting time of 24 hours is recommended.

 

 

 

Table B.2 [11] Thermal stabilization in hours

 

 

 

ÄT*

Nominal value

Class E1

Class E2

Class F1

Class F2

 

 

 

± 20 °C

1 000, 2 000, 5 000 kg

-

-

79

5

100, 200, 500 kg

-

70

33

4

10, 20, 50 kg

45

27

12

3

1, 2, 5 kg

18

12

6

2

100, 200, 500 g

8

5

3

1

10, 20, 50 g

2

2

1

1

< 10 g

1

0.5

 

 

 

± 5 °C

1 000, 2 000, 5 000 kg

-

-

1

1

100, 200, 500 kg

-

40

2

1

10, 20, 50 kg

36

18

4

1

1, 2, 5 kg

15

8

3

1

100, 200, 500 g

6

4

2

0.5

10, 20, 50 g

2

1

1

0.5

< 10 g

0.5

 

 

 

www.seoho.biz

서호 전북 전주시 덕진구 혁신로 586 (54851)

Tel. 063-214-9325 / Fax. 063-214-9328

seoho@seoho.biz

 

 


  1. No Image 16Apr
    by
    Views 284 

    국가표준기본법 [시행 2018. 12. 13] [법률 제15643호, 2018. 6. 12, 일부개정]

  2. No Image 20Mar
    by
    Views 313 

    금속표준용어집(2009)

  3. No Image 14Jun
    by
    Views 9185 

    기체유량단위

  4. No Image 19Apr
    by
    Views 1912 

    방폭의 일반

  5. No Image 19Mar
    by
    Views 3288 

    배관ANSI규격

  6. No Image 19Mar
    by
    Views 580 

    배관JIS규격

  7. No Image 12Feb
    by
    Views 5079 

    부품의 극성 및 양부 판별법

  8. 12Feb
    by
    Views 763 

    분동 허용 오차

  9. No Image 30May
    by 서호
    Views 1295 

    분동세척관련 OIML기술기준

  10. 22Feb
    by
    Views 439 

    분동의 선택방법

  11. No Image 19Mar
    by
    Views 355 

    압력 측정 방법

  12. 19Mar
    by
    Views 983 

    압력계(액주식 )

  13. No Image 19Mar
    by
    Views 631 

    압력계(탄성식)

목록
Board Pagination Prev 1 2 3 4 Next
/ 4
위로