Hoffer Flowmeters

Sanitary Flowmeter 증류수, 약품, 음료수라인 청결함을 유지해야하는 증류수, 의약품, 음용수 라인에서 사용합니다. 정밀도는 HO liquid 시리즈와같은 +/-0.5% of reading이며 클램프타입의 체결방식으로 설치 및 분리가 용이합니다.
Atachment
첨부 '2'
?

단축키

Prev이전 문서

Next다음 문서

크게 작게 뷰어로 보기 위로 아래로 댓글로 가기 인쇄
?

단축키

Prev이전 문서

Next다음 문서

크게 작게 뷰어로 보기 위로 아래로 댓글로 가기 인쇄

hrt1.jpg

 

 HART® Fiielld Communiicattiion Prrottocoll
 5 Diigiitt Ratte,, 8 Diigiitt Tottalliizerr LCD diisspllay wiitth conffiigurrablle
deciimall poiintt llocattiion
 8 Diigiitt,, Non--rressettttablle Grrand Tottall diisspllay
 Pullsse IInputt ssupporrttss tturrbiine ass wellll ass many ottherr pullsse generrattiing
ffllowmetterrss
 4--20mA Anallog Outtputt
 Up tto 20 Poiintt Liinearriizattiion
 Opttiionall Scalled Pullsse Outtputt rreprressenttiing an iincrrementt off vollume
fforr each pullsse
 Two Opttiionall Allarrm Outtputtss conffiigurrablle fforr Ratte and Tottall
 Magnettiicalllly operratted sswiittch fforr Tottall rressett
 IIntterrnall batttterry backup
 Conffiigurrattiion and Grrand Tottall ssttorred iin non--vollattiille memorry;;
Grrand Tottall ssaved once perr miinutte

Featuring 5 digits of rate and 8 digits of total, the HRT1 is a loop powered indicator capable of accepting magnetic
pickup, DC pulse or switch closure inputs. The HRT1 uses the 4-20mA loop to provide power when this output is
used and to provide the HART® communication link.

 

TOTAL DISPLAY:
8 Digits 0.26” high. Resettable
Total Units: GAL, LIT, FT3, M3, BBL &“blank”
GRAND TOTAL:
8 Digits 0.26” high, Non-resettable. Value stored once per
minute in non-volatile memory. Grand Total is displayed for
15 seconds after pressing the  button.
RATE DISPLAY:
5 Digits 0.5” High, Display updates once every two seconds
Rate Units: /SEC /MIN /HR /DAY
K-factor: The pulses per unit of Total (e.g. pulses/gallon) are
configurable in the range 0.001 to 99,999,999
Linearization: Up to 20 points
Decimal Points: Configurable for 0, .0, .00 or .000 for
rate and total
Accuracy: Total: ±1 count, Rate: ±0.01%

 

INPUTS
Magnetic Pickup:
Frequency Range: 0.2 Hz to 5000 Hz
Signal Level: 30 mVp-p to 30Vp-p
Opto-Isolated DC Pulse:
Frequency Range: 0 Hz to 3000 Hz
Signal Type: DC Pulse
High (Logic 1): 4 to 30 VDC
Low (Logic 0): <1 VDC
Min Pulse Width: 0.1 msec
Contact Closure:
Frequency Range: 0 to 5000 Hz
Signal Type: Contact closure, Sig+ Terminal to DC common
Internal Pull-up: 220 K to +3.3 VDC
Reset:
Signal Type: Contact closure, Reset Terminal to DC common
Min On: 25 msec
Internal Pull-Up: 100K to +3.3 VDC
External Magnet: Activates internal magnetic switch

 

www.seoho.biz

서호 전북 전주시 덕진구 혁신로 586 (54851)

Tel. 063-214-9325 / Fax. 063-214-9328

seoho@seoho.biz


  1. HOFFER Conditioners-Amplifiers-Transmitters Product Bulletin CAT1-001H

    Loop powered 4-20mA.  Optional flowmeter linearization.  Factory configured when purchased with a Hoffer flowmeter.  Several enclosure options.  CE Compliant.  Windows® Configuration Software. Input Signal Type: Magnetic pickup...
    By서호 Views10593
    Read More
  2. HOFFER Redi-Pulse Pickup Coil Product Bulletin RP-104D

    OUTSTANDING FEATURES  Pickup coil includes a self-contained preamplifier which provides a conditioned pulse output.  Both magnetic and modulated carrier pickup coils are available.  Eliminates peripheral signal conditioning modules an...
    By서호 Views9364
    Read More
  3. HOFFER Industrial Star Series Turbine Flow Meters for Liquids

    Industrial Star Series Turbine Flow Meters for Liquids Turbine flowmeters – Liquid flow metering The Hoffer Industrial Star Series Turbine Flowmeters are designed and manufactured for process liquids where cost is of primary concern. ...
    By서호 Views1848
    Read More
  4. HOFFER Sanitary Turbine Flowmeters Model HO3A

    SANITARY TURBINE FLOWMETER FOR PROCESS LIQUID MEASUREMENT The Hoffer Sanitary Design Turbine flowmeter is designed and manufactured to be compliant with the ASME Bioprocessing Equipment Standard BPE-2012 for measurement of process liquids wh...
    By서호 Views605
    Read More
  5. HOFFER Digital to Analog Converter Mag Type (for use with Lo-Co and TriFlo Series) Product Bulletin PET-102D

    MODEL NUMBERS PET-1 0 to 10 VDC analog output PET-3 4 to 20 mA analog output 3-wire PET-7 4 to 20 mA analog output 2-wire The PET Series converter receives frequency input and converts it to a proportional 4-20mA or 0-10V analog output. It h...
    By서호 Views451
    Read More
  6. HOFFER HO SERIES Turbine Flowmeters for Gas Service Product Bulletin HO-G-110M

    HO SERIES Turbine Flowmeters for Gases Sizes 1/4”-12” Turbine flowmeters, Gas precision flow measurement OUTSTANDING FEATURES Low cost. Outstanding accuracy. Linearity of +/-1% of reading typical. Linearity is density-dependent f...
    By서호 Views430
    Read More
  7. International Inquiry Request Form

    International Inquiry Request Form
    By서호 Views397
    Read More
  8. HOFFER Rate Indicator/Totalizer with HART® Communication Protocol Product Bulletin HRT1-111K

     HART® Fiielld Communiicattiion Prrottocoll  5 Diigiitt Ratte,, 8 Diigiitt Tottalliizerr LCD diisspllay wiitth conffiigurrablle deciimall poiintt llocattiion  8 Diigiitt,, Non--rressettttablle Grrand Tottall diisspllay  Pullsse I...
    By서호 Views312
    Read More
  9. HOFFER TURBINE FLOWMETERS FOR LIQUID SERVICE HO-STAR-105H

    HO STAR 액체 측정용 터빈유량계 최초 1968년에 출시되어 현재까지도 여러 산업분야에서 사용하고있는 터빈유량계 입니다. Simplicity(단순), Timely deliveries(빠른배송), Accuracy(정밀도), Reliability(신뢰)의 앞글자이며 가격 대비 우수한 정밀도와 구...
    By서호 Views108